Products:
Glutaraldehyde Workstations
|
Gluteraldehyde
Workstations
Environmental Protection for Hospitals, Surgicenters and Physicians'
Offices
Airfiltronix recognizes the need for protecting personnel from
highly toxic disinfectants and sterilizing solutions. The G-36G and G-53G
hoods are protective hoods designed specifically to contain fumes from liquid
sterilant/high level disinfectants.
Two models are available for endoscope manual washing/disinfecting locations.
The G-36G handles one soaking tray and one rinsing tray and the G-53G will
handle multiple soaking trays.
The system utilizes a two stage activated charcoal filter bed impregnated
with a glutaraldehyde neutralizer. A filter monitoring port on the front
of the blower base allows for monitoring of a sealed air space between the
two filter beds. This enables the user to test the air space between the
two filters to determine breakthrough of glutaraldehyde after the first
filter, allowing replacement well before exposure limits are reached by
the second filter. Typical replacement time for this filter is one year.
All hoods are baffled to concentrate airflow directly over soaking trays.
In addition, the blower has two switched speeds. When the door is closed
a face velocity of 80 fpm is maintained. When the door is opened a higher
blower speed is automatically selected to compensate for drop in face velocity.
Options:
C1- cart for G-36G Hood Contact us to discuss your requirements
C2- cart for G-53G Hood Contact us to discuss your requirements
Acrylic Polish: Anti Static surface
Light Kit
Specifications |
Model No. |
|
|
Overall Size |
32.5"H x 36"W x 21"D |
32.5"H x 53"W x 21"D |
Workspace: |
17"H x 34"W x 20"D |
17"H x 51"W x 20"D |
Power Requirements: |
115V AC, 100W, 50/60 Hz, 230V AC
optional for export |
Weight: |
76 lbs. |
120 lbs. |
Blower: |
530 CFM, (free air), Backward Curved
Impeller |
Noise Level: |
A weighted noise level 68 dB at
1 meter. |
|
Airflow Performance Statistics
|
Unit |
G-36G
|
G-53G
|
Filters Installed |
Max Airflow
CFM
|
Face Velocity
FPM
|
Max Airflow
CFM
|
Face Velocity
FPM
|
FRC-9 |
60
|
80
|
120
|
80
|
All numbers refer to average readings taken at full blower speed
|
Please Note: We can manufacture this unit in many different sizes and/or configurations. Please contact us to discuss your application or send us your specifications. Custom Design Specifications Worksheet
NOTE:
The above units are supplied without filters. G-36G and G-53G accept special dual stage FRC-9 Gluteraldehye Filters. Click here for information on FRC-9 Filter

|
 |